Home » Power Supply Units » Uninterrupted Power Supply (UPS) »

20kva Low Frequency Online UPS

20kva Low Frequency Online UPS

20kva Low Frequency Online UPS

  • Product Details
    The True Online doble conversion technology provide  clean and safe energy to all the devices on your netwrok, communication systems, and critical loads. The  Digital Signal Processing (DSP)  technology  allow the UPS take faster response to different kind of power problems, keeping the load working. His advance battery charging system allow the UPS to offer long backup time, short recharge , the temperature compensation system help to  increase the life of the batteries. His  simplified circuit controls make our products smaller, lighter and increase the confiability, reducing the number of internal componets. Main Features:   •From 20 Kva up to 200•TRUE ON LINE DOBLE CONVERSION  Technology.•100% microcontrolled by DSP.•N + 1, parallel and redundant•High efficiency > 92% •Dual Input (optional)•100% un balanced load allowed•Cold start function•Smart battery control function.•Generator compatible  Specifications:ModelGP33-20GP33-30GP33-40~60GP33-80~100GP33-120~200Capacity20 KVA30 KVA40 ~ 60 KVA80 ~ 100 KVA120 ~ 200 KVATypeTowerInput Voltage(*)380/220V ± 20%   /   4  wires (3 lines + Neutral + Ground)Max Current / Freq125%  /   60Hz  ± 10% autosensingPower Factor / Filters>0.9 (full load.)   /   EMI, RFIDual inputOptionalOutput Voltage  (*)380/220V ± 20%   /   4  wires (3 lines + Neutral + Ground)Frequency60 Hz ± 0.1%Efficiency / transfer timeAC/AC >92% /  0 mswave formSine WaveVoltage T.H.D.<2% with linear load,  <5% with nonlinear loadCrest factor / power factor3:1 /  0.9TechnologyTrue On-Line double conversion controlled by microcontrollerOverload recoveryautomatically transfer to  UPS modeisolation transformerOn UPS mode, (on bypass mode is optional)Battery Battery typeVRLA (Valve Regulated Lead Acid) not includedRecharge time4 hours up to 90%Battery testAuto-test, Transfer to battery mode adjustableProtections hardware protectionsinput Breaker, Output Breaker, Battery breaker, Bypass breaker; DC Fuse, Fan, redundant power supply; temperature sensor, EPO (Emergency Power Off), audible alarmsSoftware ProtectionsDischarging batteries, Battery charger working, Inverter working, Emergency Power Off, manual Shutdown, Bypass SCR fail, bypass sequence fail, Bypass over the limit, critical overload, battery exhausted, low output voltage, high output voltage, DC fuse open, %v power supply fail, 13.5 v power supply fail, inverter overvoltage, 200% overload on each line, transfer fail, inverter voltage out of range, voltage between neutral and ground high, UPS on Bypass mode, Bypass frequency out of range.Bypasssolid state,Overload125% for 10 min, 150%  for 30 sec, 1000%  for 1 cycle.EPOEPO local and/or remoteDisplayLCDLED´s diagramincludedCommunicationserial port RS-232, SNMP(RJ-45) (SNMP card not included)Environment Elevation/ humidity1.700 m.o.s.l without derrating / 0 a 95% non condensatetemperature / noise0° a 40° C / <60 dB  @ 1,5 m.Dimension Dimension520X1600X550520X1670X7801000X1860X870ask for information.Weight (without batteries150300600  
Contact US
  • Green Power Electronics (Shenzhen) Co., Ltd.
  • Contact Person: Mr. Tate Cheng
  • Telephone: 86-0755-29172521
  • Fax: 86-0755-27337232
  • Mobile Phone: 15019453160
  • Address: Building NO. 26, Xinwei the Third Industrial Park, Fenghuang Village, Fuyong Town, Baoan District, Shenzhen City
  • Country: China (Mainland)
  • Zip: 518103